LINC Asia-Pacific 2015 Live Case Guide

Find all Live Cases and Live Case Centers listed below.

Beijing Military Hospital 301, Beijing, China

3 livecase(s)
  • Tuesday, March 10th: - , Main Arena

    Case 13 – Occlusion of left popliteal and tibial arteries

    Center:
    Beijing Military Hospital 301, Beijing, China
    Case 13 – BMH 01: male, 72 years
    Operators:
    • Wei Guo,
    • Xin Jia
    CLINICAL DATA
    PAOD Rutherford 4
    Rest pain at left foot
    Smoking for 30 years
    Coronary artery disease
    ABI left 0.5; right 0.7

    PROCEDURAL STEPS
    1. Antegrade access and placement of a long sheath
    - 0.035" Radiofocus Terumo angled soft guidewire, 180 cm (TERUMO)
    - 6F Flexor Straight sheath, 55 cm (COOK)

    2. Passage of the lesion with hydrophilic wire and predilatation
    - 0.018" V-18 control wire, 300 cm (BOSTON SCIENTIFIC)
    - 4/120 mm Pacific balloon dilatation catheter for POP, 130 cm (MEDTRONIC)
    - 2/120 mm DEEP balloon dilatation catheter for PA and PT, 130 cm (MEDTRONIC)

    3. Retrograde AT or PA puncture in case of antegrade failure
    - 0.018" V-18 control wire, 300 cm (BOSTON SCIENTIFIC)
    - 2/80 mm DEEP balloon dilatation catheter, 130 cm (MEDTRONIC)
    View image
  • Wednesday, March 11th: - , Main Arena

    Case 21 – Infra-renal abdominal aortic aneurysm

    Center:
    Beijing Military Hospital 301, Beijing, China
    Case 21 – BMH 02: male, 75 years
    Operators:
    • Wei Guo,
    • Xin Jia
    CLINICAL DATA
    Documented abdominal aortic aneurysm in May 2012
    Coronary artery disease
    Hypertension

    ANGIOGRAPHY
    CT angiography of abdominal aorta shows:
    Maximum aneurysm diameter 60/57 mm, short and angulated neck
    Right iliac: CIA 18 mm, EIA 9 mm
    Left iliac: CIA 14 mm, EIA 11 mm

    PROCEDURAL STEPS
    1. Bilateral percutanous femoral artery access
    - Perclose preloaded (ABBOTT)

    2. Left brachial artery access for provisional chimney stent
    - 6F 90 cm Flexor long sheath (COOK)
    - Chimney stent in left renal artery: Genesis 6-18 (CORDIS)

    3. Stent graft
    - ENDURANT (MEDTRONIC)
    - Main body from left access: 28-16-170 mm
    - Right leg: 16-20-120 mm
    View image
  • Wednesday, March 11th: - , Main Arena

    Case 23 – Occlusion of left superficial femoral artery

    Center:
    Beijing Military Hospital 301, Beijing, China
    Case 23 – BMH 03: male, 65 years
    Operators:
    • Wei Guo,
    • Xin Jia
    CLINICAL DATA
    PAOD Rutherford 3
    Intermittent claudication of left leg
    Diabetes mellitus for 20 years
    ABI left 0.45, right 0.72

    PROCEDURAL STEPS
    1. Retrograde access of right groin
    - 0.035" Radiofocus Terumo angled soft guidewire, 180 cm (TERUMO)
    - 6F Flexor straight sheath, 50 cm (COOK)

    2. Passage of the lesion
    - 0.018" V-18 control wire, 300 cm (BOSTON SCIENTIFIC)
    - 4/120 mm Pacific dilatation catheter, 120 cm (MEDTRONIC)

    3. Dilatation and provisional stent
    - 4/120 mm Pacific dilatation catheter,120 cm (MEDTRONIC)
    - 6/150 mm Complete SE Nitinol vascular stent, 120 cm (MEDTRONIC)

    4. Retrograde SFA puncture in case of antegrade failure
    - 0.018" V-18 control wire, 300 cm (BOSTON SCIENTIFIC)
    - 4/120 mm Pacific dilatation catheter, 120 cm (MEDTRONIC)
    View image