Beijing Military Hospital 301, Beijing, China

3 livecase(s)
  • Tuesday, March 10th: - , Main Arena

    Case 13 – Occlusion of left popliteal and tibial arteries

    Center:
    Beijing Military Hospital 301, Beijing, China
    Case 13 – BMH 01: male, 72 years
    Operators:
    • Wei Guo,
    • Xin Jia
    CLINICAL DATA
    PAOD Rutherford 4
    Rest pain at left foot
    Smoking for 30 years
    Coronary artery disease
    ABI left 0.5; right 0.7

    PROCEDURAL STEPS
    1. Antegrade access and placement of a long sheath
    - 0.035" Radiofocus Terumo angled soft guidewire, 180 cm (TERUMO)
    - 6F Flexor Straight sheath, 55 cm (COOK)

    2. Passage of the lesion with hydrophilic wire and predilatation
    - 0.018" V-18 control wire, 300 cm (BOSTON SCIENTIFIC)
    - 4/120 mm Pacific balloon dilatation catheter for POP, 130 cm (MEDTRONIC)
    - 2/120 mm DEEP balloon dilatation catheter for PA and PT, 130 cm (MEDTRONIC)

    3. Retrograde AT or PA puncture in case of antegrade failure
    - 0.018" V-18 control wire, 300 cm (BOSTON SCIENTIFIC)
    - 2/80 mm DEEP balloon dilatation catheter, 130 cm (MEDTRONIC)
    View image
  • Wednesday, March 11th: - , Main Arena

    Case 21 – Infra-renal abdominal aortic aneurysm

    Center:
    Beijing Military Hospital 301, Beijing, China
    Case 21 – BMH 02: male, 75 years
    Operators:
    • Wei Guo,
    • Xin Jia
    CLINICAL DATA
    Documented abdominal aortic aneurysm in May 2012
    Coronary artery disease
    Hypertension

    ANGIOGRAPHY
    CT angiography of abdominal aorta shows:
    Maximum aneurysm diameter 60/57 mm, short and angulated neck
    Right iliac: CIA 18 mm, EIA 9 mm
    Left iliac: CIA 14 mm, EIA 11 mm

    PROCEDURAL STEPS
    1. Bilateral percutanous femoral artery access
    - Perclose preloaded (ABBOTT)

    2. Left brachial artery access for provisional chimney stent
    - 6F 90 cm Flexor long sheath (COOK)
    - Chimney stent in left renal artery: Genesis 6-18 (CORDIS)

    3. Stent graft
    - ENDURANT (MEDTRONIC)
    - Main body from left access: 28-16-170 mm
    - Right leg: 16-20-120 mm
    View image
  • Wednesday, March 11th: - , Main Arena

    Case 23 – Occlusion of left superficial femoral artery

    Center:
    Beijing Military Hospital 301, Beijing, China
    Case 23 – BMH 03: male, 65 years
    Operators:
    • Wei Guo,
    • Xin Jia
    CLINICAL DATA
    PAOD Rutherford 3
    Intermittent claudication of left leg
    Diabetes mellitus for 20 years
    ABI left 0.45, right 0.72

    PROCEDURAL STEPS
    1. Retrograde access of right groin
    - 0.035" Radiofocus Terumo angled soft guidewire, 180 cm (TERUMO)
    - 6F Flexor straight sheath, 50 cm (COOK)

    2. Passage of the lesion
    - 0.018" V-18 control wire, 300 cm (BOSTON SCIENTIFIC)
    - 4/120 mm Pacific dilatation catheter, 120 cm (MEDTRONIC)

    3. Dilatation and provisional stent
    - 4/120 mm Pacific dilatation catheter,120 cm (MEDTRONIC)
    - 6/150 mm Complete SE Nitinol vascular stent, 120 cm (MEDTRONIC)

    4. Retrograde SFA puncture in case of antegrade failure
    - 0.018" V-18 control wire, 300 cm (BOSTON SCIENTIFIC)
    - 4/120 mm Pacific dilatation catheter, 120 cm (MEDTRONIC)
    View image
Cookie settings

We use cookies so that we can offer you the best possible website experience. This includes cookies which are necessary for the operation of the website and to manage our corporate commercial objectives, as well as other cookies which are used solely for anonymous statistical purposes, for more comfortable website settings, or for the display of personalised content. You are free to decide which categories you would like to permit. Please note that depending on the settings you choose, the full functionality of the website may no longer be available. Further information can be found in our privacy statement and legal notice.

  • We are using cookies in order to enable the services of the website and to ensure that certain aspects work as required. The cookies within this group are essential for the correct appearance and functionality of the website. No information within these cookies will be given to third parties.

  • We're using functional tracking to analyze the usage of our website. The data hereby gathered, allows us to find errors and improve designs. It also enables us to test the efficacy of our website. These cookies furthermore help us in analyzing our advertisements and affiliate marketing.

  • Our website makes use of external services such as Issuu. These services provide great value to us and to you as a user. However they do write cookies and collect data about their usage on this website. In order for you to be able to use these services, you will have to give your consent to their respective cookies.